Skip to content

Node Overview

Asset Type: junction
Display Name: Node
Display Plural: Nodes
Geometry Type: Point

Quick Navigation

Node SubTypes

SubType KeyDisplay NameGeometryDocumentationAlso Known As
ManholeManholePointLarge inspection chamber with cover, typically in carriageway or footway; access point for underground drainage system with steps or ladder for personnel entry.
CatchpitCatchpitPointSediment trap chamber with sump for collecting silt, grit and debris before water flows to main system; settling pit for material removal.
GullyGullyPointRoad or footpath gully with grating at surface level; collects surface water runoff from carriageway, footway or kerb edge.
RoddingEyeRodding EyePointSmall access point for rodding or jetting equipment; allows drain clearing without full chamber access, typically smaller than manhole.
SoakawaySoakawayPointInfiltration chamber or rubble-filled pit allowing water to percolate into ground; drainage disposal point with no outflow pipe.
InterceptorInterceptorPointOil separator, petrol interceptor or pollution control chamber; treats contaminated water before discharge, often with baffles and Class 1/2 rating.
HeadwallHeadwallPointConcrete or masonry structure at culvert or pipe entrance/exit; retains embankment and provides structural support at channel termination.
TrashScreenTrash ScreenPointDebris screen, trash rack or coarse screen preventing large objects entering system; metal grille or bar screen at inlet.
CoverCoverPointInspection cover, access lid or chamber cover without full structure information; surface access point where details uncertain.
CattleGridCattle GridPolygonMetal grid across roadway or track allowing vehicle passage while preventing livestock crossing; drainage feature with bars over pit.
InletInletPointWater entry point or surface water inlet to drainage system; start of pipe run or channel intake location.
OutletOutletPointPipe discharge point or drainage system exit; where water leaves pipe before final outfall or next system component.
OutfallOutfallPointFinal discharge point to watercourse, river, ditch or sea; end of drainage system where water released to receiving waters.
PumpingStationPumping StationPointPumped drainage chamber with mechanical equipment; lifts water where gravity drainage is impossible, includes pump and controls.
GhostNodeGhost NodePointVirtual connection point or modelling node with no physical structure; used for network connectivity or system representation only.
HydroBrakeHydro BrakePointFlow control device or vortex valve restricting discharge rate; mechanical flow limiter for attenuation or storage control.
ConnectorConnectorPointNetwork junction point or logical connection between systems; links different drainage networks or asset ownership boundaries.
WeirWeirPointOverflow structure or water level control with notch or crest; measures or regulates flow in chamber or open channel.
PenstockPenstockPointAdjustable gate or sluice valve for flow control; manually operated metal gate controlling water level or discharge.
WaterAuthorityWater AuthorityPointAsset owned and/or maintained by the local water authority. May be of any type, details in the asset type field.
KerbInletKerb InletPointKerb opening or slot in kerb face for water entry; side-entry inlet where water enters from kerb edge rather than grating.

Node Asset Attributes

Attribute NameDisplay NameTypeEnum Values
typeStructureEnumeratedN/A
access_methodAccess MethodEnumeratedWithSupplementaryQuestionsN/A
num_stepsNumber of stepsNumberN/A
grating_typeGratingEnumeratedN/A
gully_locationGully LocationEnumeratedN/A
shaft_widthShaft WidthNumberWithUnitN/A
shaft_heightShaft HeightNumberWithUnitN/A
chamber_widthChamber WidthNumberWithUnitN/A
chamber_lengthChamber LengthNumberWithUnitN/A
depthOverall DepthNumberWithUnitN/A
chamber_shapeChamber ShapeEnumeratedN/A
cover_materialCover MaterialEnumeratedN/A
cover_shapeCover ShapeEnumeratedN/A
cover_widthCover/Grid WidthNumberWithUnitN/A
cover_lengthCover/Grid LengthNumberWithUnitN/A
cover_levelCover Level (high accuracy) (m)NumberWithUnitN/A
discharge_locationDischarge LocationEnumeratedN/A
cover_dutyCover DutyEnumeratedN/A
cover_manufacturerCover ManufacturerFreeTextN/A
cover_classCover ClassEnumeratedN/A
constructionConstructionEnumeratedN/A
has_gratingGratingNullableBooleanN/A
has_side_entrySide EntryNullableBooleanN/A
has_flap_valveFlap ValveNullableBooleanN/A
has_orificeOrificeNullableBooleanN/A
has_sluice_gateSluice gateNullableBooleanN/A
has_weirWeirNullableBooleanN/A
has_screensScreensNullableBooleanN/A
has_penstockPenstockNullableBooleanN/A
has_flumeFlumeNullableBooleanN/A
has_headwallHeadwallNullableBooleanN/A
has_boreholeBoreholeNullableBooleanN/A
has_grit_panGrit PanNullableBooleanN/A
has_sumpSump presentNullableBooleanN/A
backing_kerbBacking kerbNullableBooleanN/A
num_landingsNo. LandingsNumberN/A
usageUsageEnumeratedN/A
data_sourceData SourceFreeTextN/A
structure_locationStructure LocationEnumeratedN/A
strategicStrategicEnumeratedN/A
headwall_materialHeadwall materialEnumeratedN/A
access_gateAccess GateEnumeratedN/A
has_removable_panelRemovable panelNullableBooleanN/A
has_fencing_handrailFencing handrailNullableBooleanN/A
has_working_platformWorking platformNullableBooleanN/A
has_horizontal_screenHorizontal screenNullableBooleanN/A
has_sloping_screenSloping screenNullableBooleanN/A
has_coarse_screenCoarse screenNullableBooleanN/A
reference_numberReference numberFreeTextN/A
retentionRetentionEnumeratedN/A
interceptor_classClassEnumeratedN/A
oil_storage_capacityOil storage capacityNumberWithUnitN/A
closure_valveClosure valveNullableBooleanN/A
alarm_installedAlarm installedNullableBooleanN/A
other_shapeOther ShapeEnumeratedN/A
gully_subtypeGully TypeEnumeratedN/A
water_authority_subtypeWater Authority Node TypeFreeTextN/A
chamber_materialChamber materialEnumeratedN/A
invert_levelInvert level (min 30, max 250)NumberWithUnitN/A
dimensionDimensionEnumeratedN/A
trappedTrappedBooleanN/A
remote_access_reasonRemote accessEnumeratedN/A
needs_sweeperRequires sweeperBooleanN/A
soffitSoffitEnumeratedN/A
tail_directionTail directionEnumeratedN/A
grid_sizeGrid sizeNumberWithUnitN/A
gate_sizeGate sizeNumberWithUnitN/A
hazardHazardEnumeratedN/A
📋 Access Method Values
NameDisplay
StepIronsStep irons
LadderLadder
LandingsLandings
DavitsDavits
OtherOther
NoneNone
📋 Grating Values
NameDisplay
GrateGrate
SplitSplit
InfillInfill
OtherOther (Hinged)
Non-HingedOther (Non-Hinged)
📋 Gully Location Values
NameDisplay
CarriagewayCarriageway
CentralReservationCentral Reservation
FootwayFootway
ParkingBayParking Bay
OtherOther
📋 Chamber Shape Values
NameDisplay
CircularCircular
SquareSquare
RectangleRectangle
TriangularTriangular
OtherOther
📋 Cover Material Values
NameDisplay
Iron/ConcreteIron/Concrete
IronIron
InfillInfill
DuctileDuctile
CompositeComposite
FibreglassFibreglass
OtherOther
📋 Cover Shape Values
NameDisplay
CircularCircular
SquareSquare
RectangleRectangle
TriangularTriangular
OtherOther
📋 Discharge Location Values
NameDisplay
LowRiskLow Risk
BathingWaterBathing water
DitchesDitches
RiversRivers
SeaSea
📋 Cover Duty Values
NameDisplay
HeavyDutyHeavy
MediumDutyMedium
LightDutyLight
UnknownUnknown
📋 Cover Class Values
NameDisplay
A15A15
B125B125
C250C250
D400D400
E600E600
F900F900
UnknownUnknown
📋 Construction Values
NameDisplay
BrickBrick
PreCastConcretePrecast Concrete
InSituConcreteIn situ Concrete
BoltedConcreteSegmentsBolted Concrete segments
IronIron
IronAndConcreteIron/Concrete
OtherOther
📋 Usage Values
NameDisplay
SurfaceSurface
FoulFoul
CombinedCombined
OtherOther
📋 Structure Location Values
NameDisplay
VergeVerge
FootwayFootway
CarriagewayCarriageway
HardShoulderHard Shoulder
Lane1Lane1
Lane2Lane2
Lane3Lane3
CresRightVergeCres / Right Verge
📋 Strategic Values
NameDisplay
CentralReserveCentral Reserve
CrossDrainsCross Drains
VergeOrHardShoulderVerge / Hard Shoulder
ToeDrainsToEarthworksToe Drains to Earthworks
OtherOther Drainage System
📋 Headwall material Values
NameDisplay
BagworkBagwork
BlockworkBlockwork
BrickworkBrickwork
ConcreteConcrete
In-Situ ConcreteIn-Situ Concrete
OtherOther
📋 Access Gate Values
NameDisplay
GateGate
HatchHatch
NullNull
📋 Retention Values
NameDisplay
FullFull
BypassBypass
📋 Class Values
NameDisplay
Class1Class 1
Class2Class 2
📋 Other Shape Values
NameDisplay
RectangleRectangle
CircleCircle
OtherOther
📋 Gully Type Values
NameDisplay
SplitSplit
GrateGrate (hinged)
SideEntrySide entry
CurbInletKerb inlet
TroughTrough
OffLetOfflet
FootwayFootway Gully
ChuteChute
TopEntryTop entry
OffsetOffset
OtherNonHingedOther (non-hinged)
OtherOther
📋 Chamber material Values
NameDisplay
BrickBrick
ConcreteConcrete
MasonryBlockMasonry block
PolyethylenePolyethylene
ClayClay
CastIronCast Iron
📋 Dimension Values
NameDisplay
GullyGully
ChamberChamber
📋 Remote access Values
NameDisplay
NoneNot required
PedPedestrian area
NoAccNo access for vehicle
SubwaySubway
📋 Soffit Values
NameDisplay
CorbelCorbel
ReducingSlabReducing Slab
TaperTaper
OtherOther
NoneNone
📋 Tail direction Values
NameDisplay
CarriagewayCarriageway
FootwayFootway
ChannelChannel
📋 Hazard Values
NameDisplay
ServicesInAssetServices in asset
ShallowPipeworkShallow pipework
OtherOther

Node Inspection Attributes

Attribute NameDisplay NameTypeEnum Values
cover_conditionCover ConditionEnumeratedN/A
silt_level_nXSilt levelNumberInRangeWithUnitN/A
silt_level_nSilt LevelReflectedSliderN/A
silt_levelSilt LevelEnumeratedN/A
silt_level_positionSilt level positionEnumeratedN/A
silt_defectSilt defectTransitionalNotSetMultiValuedEnumeratedN/A
water_levelWater LevelEnumeratedN/A
pollutionEvidence of pollutionEnumeratedN/A
is_dryGully is dryBooleanN/A
operational_on_arrivalOperational on arrivalEnumeratedN/A
operational_on_leavingOperational on leavingEnumeratedN/A
junction_cleanedCleanedBooleanN/A
general_conditionGeneral conditionEnumeratedN/A
weatherWeather on InspectionEnumeratedN/A
carriageway_floodingCarriageway floodingEnumeratedN/A
weepholesWeep holesEnumeratedN/A
base_conditionCondition of BaseEnumeratedN/A
structure_conditionCondition of StructureEnumeratedN/A
scour_pad_conditionCondition of Anti Scour PadEnumeratedN/A
structure_defectsStructure defectsEnumeratedN/A
componentsComponentsEnumeratedN/A
jetting_completedJetting completedBooleanWithSupplementaryQuestionsN/A
jetting_timeJetting timeNumberInRangeWithUnitN/A
jt_water_reqWater requiredBooleanN/A
jt_travel_reqTravel requiredBooleanN/A
jt_commentReason for jettingFreeTextN/A
pot_conditionPot conditionEnumeratedN/A
cover_to_silt_depthSilt depthSiltDepthN/A
wasteWasteNumberWithUnitN/A
base_to_outletBase to OutletNumberWithUnitN/A
flood_extentFlood extentEnumeratedN/A
flood_depthFlood depthEnumeratedN/A
enhanced_cleanEnhanced CleanBooleanN/A
repair_completedRepair completedBooleanN/A
📋 Cover Condition Values
NameDisplay
OKOK
UnableToLiftStuck Cover
CrackedLidCracked Cover
BrokenLidBroken Cover
BuriedOnArrivalBuried on Arrival
MissingMissing Cover
📋 Silt Level Values
NameDisplay
0%0%
25%25%
50%50%
75%75%
100%100%
📋 Silt level position Values
NameDisplay
Over120mmBelowOutletGreater than 120mm below outlet
Within120mmOfOutletSilt within 120mm of outlet
AboveOutletSilt above outlet
📋 Silt defect Values
NameDisplay
RequiredDigOutRequired dig out
ExcessiveDebrisExcess debris
TarmacStoneTarmac/Stone
NeedlesNeedles/Sharps
LitterLitter
OilAndFatOil and fat
DomesticRefuseDomestic Refuse
LargeHouseholdRefuseLarge Household Refuse
LargeNonDomesticRefuseLarge Non-Domestic Refuse
RootsRoots
LeavesLeaves
📋 Water Level Values
NameDisplay
0%0%
25%25%
50%50%
75%75%
100%100%
📋 Evidence of pollution Values
NameDisplay
NoneNone
Foul waterFoul water
PetrolPetrol
OilOil
ChemicalChemical
📋 Operational on arrival Values
NameDisplay
YesYes - junction flowing
NoNo
SlowRunnerSlow runner
📋 Operational on leaving Values
NameDisplay
YesYes - junction flowing
NoNo
SlowRunnerSlow runner
📋 General condition Values
NameDisplay
0unknown
11
22
33
44
55
📋 Weather on Inspection Values
NameDisplay
WetWet
DryDry
📋 Carriageway flooding Values
NameDisplay
FullWidthFull width
HalfWidthHalf width
PartPart
NoneNone
📋 Weep holes Values
NameDisplay
ClearClear
BlockedBlocked
N/AN/A
📋 Condition of Base Values
NameDisplay
GoodGood
AverageAverage
NeedsRepairNeeds Attention/Repair
📋 Condition of Structure Values
NameDisplay
GoodGood
AverageAverage
NeedsRepairNeeds Attention/Repair
📋 Condition of Anti Scour Pad Values
NameDisplay
GoodGood
AverageAverage
NeedsRepairNeeds Attention/Repair
📋 Structure defects Values
NameDisplay
StructuralCrackStructural Crack
FracturedFractured
BrokenBroken
UnsafeUnsafe
📋 Components Values
NameDisplay
DamagedBaffleDamaged Baffle
LooseUnseatedFlapValveLoose or Unseated Flap Valve
MissingVentPipeFromOilSeparatorMissing Vent Pipe from Oil Separator
MissingWeirSectionsMissing Weir Sections
SeizedFlapValveSeized Flap Valve
MissingHandRailMissing Hand Rail
📋 Pot condition Values
NameDisplay
CrackedCracked
CollapsedCollapsed
📋 Flood extent Values
NameDisplay
LessThan5m2Less than 5 m2
5-20m25 - 20 m2
20-100m220 - 100 m2
MoreThan100m2More than 100 m2
📋 Flood depth Values
NameDisplay
LessThan25mmLess than 25 mm
25-100mm25 - 100 mm
100-300mm100 - 300 mm
MoreThan300mmMore than 300 mm

Node Service Requests

OperationDisplay Name
inspectInspect
rectify_unknown_faultRectify unknown fault
investigateRequires investigation
cleanClean
jettingJetting
root_cuttingRoot cutting
cctv_surveyCCTV survey
connection_excavationConnection excavation
main_line_cleanMain line clean
pot_design_changePot design change
dig_outDig out
release_lidLid release
cover_replacementCover replacement
unblock_ditchUnblock ditch
refer_to_clientRefer to client
bung_replacementBung Replacement
hedge_cuttingHedge Cutting
desiltingDesilting
repairRepair

Contacts (optional)

  • Internal business owner
  • Technical lead(s)
  • 3rd party contact details